7. All content s are Copyright © 1996 - 2 0 1 9 Wavesplitter Technologies, Inc. All rights reserved . Preliminary and Proprietary www.wavesplitter.com Page 7 of 10 Document Number: 95 - 0189 - V1. 2 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 Transceiver WST - S28 - BX1 - DC OWRAP enable MODE (I2C Controlled) Ewrap forward enable MODE (I2C Controlled) E wrap enable MODE (I 2C Controlled) SFP+ Connect or SFP+ Connector SFP+ Connector

5. All content s are Copyright © 1996 - 2 0 1 9 Wavesplitter Technologies, Inc. All rights reserved . Preliminary and Proprietary www.wavesplitter.com Page 5 of 10 Document Number: 95 - 0189 - V1. 2 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 Transceiver WST - S28 - BX1 - DC Recommended Circuit Schematic Mechanical drawing Units in mm Note: Specifications subject to c hange without notice. 1 2 3 4 5 6 A B C D 6 5 4 3 2 1 D C B A Titl e Nu mber R ev i sio n Size B Dat e: 1 1-Ju l-2 00 7 Sheet o f File: D:\ WOR K\s ch .d d b Drawn B y: 0.1μF 22 μF 0.1μF 22 μF Vee R POST Am p LD Driver Z=50Ω Z=50Ω Z=50Ω Z=50Ω Vee T 4 .7 μH 4 .7 μH TD - TD + Vcc T Vcc R RD - RD + 100Ω SFP+ module SerDe s 100Ω LOS RD - RD + TD - TD + 0.1μF Protocol EEPROM MODULE DETECT SCL SDA LOSS OF SINGAL Tx_DISABLE Tx_FAULT MOD_ABS SCL SDA 10 KΩ 10 KΩ 10 KΩ 10 KΩ Tx_FAULT Tx_DISABLE (1,17,20) 3 2 18 19 16 15 12 13 8 (10,11,14) 6 5 4 10 KΩ Vcc 3.3V Vcc 3.3V IC IC de pending on SERDES 0.1μF 30KΩ 30KΩ RS1 RS0 7 9 TX Rate Select RX Rate Select

6. All content s are Copyright © 1996 - 2 0 1 9 Wavesplitter Technologies, Inc. All rights reserved . Preliminary and Proprietary www.wavesplitter.com Page 6 of 10 Document Number: 95 - 0189 - V1. 2 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 Transceiver WST - S28 - BX1 - DC WRAP and BYPASS CDR operation fu nctions - Soft Co ntrol (Address A2h, Byte 111). T o assist with local host or remote diagnostic and optimization sequences , e lectrical and optical wrap functions can be enabled. Optical wrap (OWRAP) take s the received optical signal through CDR s and retrans mits it optically out. Electrical wrap (EWRAP) takes the received electrical signal through CD Rs and retransmits it electrically out. O ptional forward function s can be transmit ted outbound the wrapped i nformation via i2c co ntrol . Byte Bit Name Description 111 4 - 7 Reserved Reserved. 3 OWRAP Forward Enable Bit When set in combination with OWRAP Enable, OWRAP Forward routes incoming SFP+ Rx optical data to both the Tx optical output and the Rx electrica l output. Enabling sets bit 2 and clears all other bit s in byte 111. 2 OWRAP Enable Bit When set, OWRAP routes incoming SFP+ Rx optical data to the Tx optical output. Enabling clears all other bits in byte 111. 1 EWRAP Forward Enable Bit When set in co mbination with EWRAP Enable, EWRAP Forward routes inco ming SFP+ Tx electrical data to both Rx electrical output and Tx optical output. Enabling sets bit 0 and clears all other bits in byte 111. 0 EWRAP Enable Bit When set, EWRAP Enable routes incoming SF P+ Tx electrical data to the Rx electrical output. Ena bling clears all other bits in byte 111. OWRAP FORWARD enable MODE (I2C Controlled) SFP+ Connector

3. All content s are Copyright © 1996 - 2 0 1 9 Wavesplitter Technologies, Inc. All rights reserved . Preliminary and Proprietary www.wavesplitter.com Page 3 of 10 Document Number: 95 - 0189 - V1. 2 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 Transceiver WST - S28 - BX1 - DC Electrical Characteristics Parameter Symbol Min Typ Max Units Notes High - Speed Signal (CML) Interface Specification Input Data Rate 24.33/25.78 Gb/s TX Clock Tolerance - 100 +100 ppm 4 Differential Input Impedance Rin 100 Ω Differential Data Input Amplitude 150 1000 mVpp Internally AC coupled Output Data Rate 8.5 25.78 Gb/s RX Clock Tolerance - 100 +100 ppm 4 Differential Output Impedance Rout 100 Ω Differential Data Output Amplitude 350 600 700 mVpp Interna lly AC coupled Low - Speed Signal (LVTTL) Interface Specification Input High Voltage 2.0 Vcc+0.3 V Input Low Voltage GND 0.8 V Output High Voltage 2.4 Vcc V Output Low Voltage GND 0.5 V Notes: 1. Clock tolerance for 24.33Gb/s and 25.78Gb/s C onnection D iagram

1. Data Sheet All contents a re Copyright © 1996 - 20 1 9 Wavesplitter Technologies, Inc. All rights reserved. P reliminary and Proprietary www.wavesplitter.com Page 1 of 10 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 TR ANSCEIVER P/N: WST - S28 - BX1 - DC Description WST - S28 - BX1 - DC series single mode transceiver is a small form factor pluggable module for bi - directional serial optical data communications such as 25G Ethernet and CPRI Option 10. It is with the SFP+ 20 - pin connector to allow hot plug capability. Digital diagnostic func tions are available via an I2C. The transmitter section uses a 1270 nm multiple quantum well DFB laser and is a class 1 laser compliant according to International Safety Standard IEC - 60825. The receiver section uses an integrated InGaAs detector preamplifi er (IDP) mounted in an optical header and a rate selection clock data recovery (CDR) IC . Features : ◼ 1 - Fiber Bi - Directional SFP Optical Transceiver ◼ Up to 25.78 Gbps Bi - directional Data Links ◼ Complaint with SF F - 8402 SFP28 MSA ◼ Support 25G Ethernet ◼ Support CPRI Option 10 @ 24. 33 Gbps ◼ Built - in dual CDR ◼ Distance up to 10 km ◼ Si mplex LC Connector ◼ 1270nm DFB Tra nsmitter ◼ 1330nm Receiver ◼ SFF - 8472 Digital Diagnostic Function ◼ AC/AC Coupling according to MSA ◼ Single +3.3 V P ower Supply ◼ RoHS 6/6 Compliant ◼ 0 to 70 °C Operation: WST - S28 - BX1 - DC ◼ - 2 0 to 85 °C Operation: WST - S28 - BX1 - D E ◼ - 40 to 85 °C Operation: WST - S28 - BX1 - D I ◼ Class 1 Laser International Safety Standard IEC - 60825 Compliant ◼ Enhanced EWRAP and OWRAP operational features Applications: ◼ 25G Ethernet ◼ CPRI Option 10

4. All content s are Copyright © 1996 - 2 0 1 9 Wavesplitter Technologies, Inc. All rights reserved . Preliminary and Proprietary www.wavesplitter.com Page 4 of 10 Document Number: 95 - 0189 - V1. 2 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 Transceiver WST - S28 - BX1 - DC PIN Signal Name Description PIN Signal Name Description 1 V EE T Transmitter Signal Ground 11 V EE R Receiver Signal Ground 2 TX_Fault Transmitter Fault Indication. Logic “ 1 ” Output = Laser Fault. Logic “ 0 ” Output = Normal Operation 12 RD - Inverse Receiver Data Out 3 TX_Di sable Logic “ 1 ” Input (or no connection) = Laser off, Logic “ 0 ” = Laser on . 13 RD+ Receiver Data Out 4 SDA Modulation Definition 2 – Two wires serial ID Interface 14 V EE R Receiver Signal Ground 5 SCL Modulation Definition 1 – Two wires serial ID Interf ace 15 V CC R Receiver Power – 3.3V ± 5% 6 MOD - ABS Modulation Definition 0 – Ground in Module 16 V CC T Transmitter Power – 3.3V ± 5% 7 RS0 RX Rate Select: This pin has an internal 30k pull down to ground. A signal on this pin will not affect module performance . 17 V EE T Transmitter Signal Ground 8 RX_LOS Loss of Signal Out (OC). 18 TD+ Transmitter Data In 9 RS1 TX Rate Select: This pin has an internal 30k pulldown to ground. A signal on this pin will not a ffect module performance. 19 TD - Inverse Transmitter Data In 10 V EE R Receiver Signal Ground 20 V EE T Transmitter Signal Ground Module Definition Module Definition PIN 4 PIN 5 PIN 6 Interpretation by Host 4 SDA SCL MOD - ABS Serial module definition proto col Module Definition 4 specifies a serial definit ion protocol. For this definition, upon power up, SDA and SCL appear as no connector (NC) and MOD - ABS is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the 2 - wire serial CMOS E 2 PROM protocol of the ATMEL AT24C01A/02/04 family of components.

10. Page 10 of 10 Document Number: 95 - 0189 - V1. 2 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 Transceiver WST - S28 - BX1 - DC Orderi n g I n f o rmation P/No. Bit Rate (Gb/s) CPRI D istance (km) Wavelength (nm) Package Case Temp ( o C ) RoHS Compliant WST - S28 - BX1 - DC Up to 25. 78 Option 10 10 1330 DFB SFP28 with DMI 0 to 70 Yes WST - S28 - BX1 - D I Up to 25. 78 Option 10 10 1330 DFB SFP28 with DMI - 4 0 to 8 5 Yes WST - S28 - BX1 - D E Up to 25. 78 Option 10 10 1330 DFB SFP28 with DMI - 2 0 to 8 5 Yes Modification History Revision Date Description Originator Review Approved V 1 30 - Apr - 20 1 8 New Issue (Preliminary ) Ivy Chen Wayne Liao Wayne Liao V1 .1 16 - N ov - 2018 Final v ersion Ivy Chen Wayne Liao Wayne Liao V1.2 11 - Jan - 2019 U pdate picture Ivy Chen Wayne Liao Wayne Liao All specification data are accurate on the da te of publication for product co mparisons and ordering information. WaveSp litter Technologies, Inc. reserves the right to change specifications wit hout notice. U.S. Branc h 2080 Rancho Higuera Ct. Fremont, CA 9 45 3 9, USA Tel: 510 - 651 - 7800 Fax: 510 - 651 - 7822 Taipei Headquarters 16F - 5, No. 75, Sec. 1, Xintai 5th Rd., Xizhi Dist. , New Taipei C ity 221 01 , Taiwan Tel: +886 - 2 - 2 698 - 7208 Fax: +886 - 2 - 2 698 - 7210 ShenZhen Branch 610# , 6F, No.204 Building, 2nd Industrial zone Nanyou, Nanshan district, Shenzhen, Guangdong China 518054 Tel: +86 - 755 - 86265980 Fax: +86 - 755 - 26642741

2. All content s are Copyright © 1996 - 2 0 1 9 Wavesplitter Technologies, Inc. All rights reserved . Preliminary and Proprietary www.wavesplitter.com Page 2 of 10 Document Number: 95 - 0189 - V1. 2 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 Transceiver WST - S28 - BX1 - DC Abs o lute Maximum Ratings Parameter Symbol Min Max Units Notes Storage Temperature Tstg - 40 85 o C Relative Hu midity RH 5 85 % Non - condensing Operating Case Temperature Topr 0 - 20 - 40 70 85 85 o C WST - S28 - BX1 - DC WST - S28 - BX1 - D E WST - S28 - BX1 - D I Power Supply Voltage Vcc - 0.5 3.6 V Receiver Input Optical Power Mip 3 dBm Average power Recommended Operating Conditi ons Param eter Symbol Min Typ Max Units / Notes Power Supply Voltage Vcc 3.135 3.3 3.465 V Operating Case Temperature Topr 0 - 20 - 40 70 85 85 WST - S28 - BX1 - DC WST - S28 - BX1 - D E WST - S28 - BX1 - D I Relative Humidity RH 5 85 % / Non - condensing Power Supply Curren t I CC (TX +RX) 270 340 mA Data Rate 24.33 / 25.78 Gb/s Transmitter Optical Specifications ( 0 oC < Topr < 7 0 oC, 3.1 3 V < Vcc < 3. 47 V) Parameter Symbol Min Typ Max Units Notes Average Launch Power Po, AVG 1 5 dBm 1 Output Center Wavelength l c 1260 127 0 1280 nm Output Spectrum Width Dl --- 1 nm - 20 dB width Side Mode Suppression Ratio SMSR 30 dB Extinction Ratio ER 3.5 dB Transmitter and Dispersion Penalty TDP 2.7 dB Relative Intensity Noise RIN - 130 dB/Hz Average Launch Power of OFF Transmit ter - 30 dBm Notes: 1. Output power is power coupled into a 9/125  m single - mode fiber. Receiver Op tical Specifications ( 0 oC < Topr < 70 oC, 3.1 3 V < Vcc < 3. 47 V) Parameter Symbol Min Typ Max Units Notes Sensitivity - 11 dBm 2, Average Power Receiver Overload P MAX +2 --- dBm LOS – Deasserted LOS D --- --- - 14 dBm T ransition: low to high LOS – Asserted LOS A - 26 --- --- dBm Transition: high to low Wavelength of Operation l c 1320 1340 nm 3 Notes: 1. Measured with worst ER; BER < 10 - 6 and PRBS 2 31 - 1. 2. At least 30 dB optical isolation for the wavelength 1260 to 1280 nm.

9. All content s are Copyright © 1996 - 2 0 1 9 Wavesplitter Technologies, Inc. All rights reserved . Preliminary and Proprietary www.wavesplitter.com Page 9 of 10 Document Number: 95 - 0189 - V1. 2 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 Transceiver WST - S28 - BX1 - DC EEPROM Series ID Memory Contents (Address A2h) Addr . Hex Note Addr . Hex Note Addr . Hex Note Addr . Hex Note 0 4B Temp. High Alarm (75oC) 32 4D Rx Power High Alarm (3dBm) 64 00 For External Cal. 96 R eal Time Temp. MSB 1 00 33 F1 65 00 For Exte rnal Cal. 97 Real Time Temp. LSB 2 FB Temp. Low Alarm( - 5oC) 34 01 Rx Power Low Alarm ( - 14dBm) 66 00 For External Cal. 98 Real Time Vcc MSB 3 00 35 8E 67 00 For External Cal. 99 Real Time Vcc LSB 4 49 T emp. High Warming(73oC) 36 3D Rx Power High War ming (2dBm) 68 3F For External Cal. 100 Real Time Tx Bias MSB 5 00 37 E9 69 80 For External Cal. 101 Real Time Tx Bias LSB 6 00 Temp. Low Warming (0oC) 38 02 Rx Power Low Warming( - 12dBm) 70 00 For Exte rn al Cal. 102 Real Time Tx Pwr MSB 7 00 39 27 71 00 For External Cal. 103 Real Time Tx Pwr LSB 8 8C Voltage High Alarm (3.6V) 40 00 Reserved 72 00 For External Cal. 104 Real Time Rx Pwr MSB 9 A0 41 00 Reserved 73 00 For External Cal. 105 Real Tim e Rx Pwr LSB 10 75 Voltage Low Alarm(3.0V) 42 00 Reserved 74 00 For External Cal. 106 Reserved 11 30 43 00 Reserved 75 00 For External Cal. 107 Reserved 12 88 Voltage High Warming(3.5V) 44 00 Reserved 76 01 For External Cal. 108 Reserved 13 B8 45 00 Reserved 77 00 For External Cal. 109 Reserved 14 79 Voltage Low Warming (3.1V) 46 00 Reserved 78 00 For External Cal. 110 Tx Dis, Tx Fault, Rx Los 15 18 47 00 Reserved 79 00 For External Cal. 111 OWRAP, EWRAP 16 AF Tx Bias High Alarm(90mA) 48 00 Re served 80 01 For External Cal. 112 Alarm Flag 17 C8 49 00 Reserved 81 00 For External Cal. 113 Alarm Flag/Reserved 18 03 Tx Bias Low Alarm(2mA) 50 00 Reserved 82 00 For External Cal. 114 Reserved 19 E8 51 00 Reserved 83 00 For External Cal. 115 Re served 20 9C Tx Bias High Warming(80mA) 52 00 Reserved 84 01 For External Cal. 116 Warming Flag 21 40 53 00 Reserved 85 00 For External Cal. 117 Warming Flag/Reserved 22 07 Tx Bias Low Warming(4mA) 54 00 Reserved 86 00 For External Cal. 118 Reserv ed 23 D0 55 00 Reserved 87 00 For External Cal. 119 Reserved 24 9B Tx Power High Alarm (6dBm) 56 00 For External Cal. 88 01 For External Cal. 120 Vendor Specific 25 83 57 00 For External Cal. 89 00 For External Cal. 121 26 27 Tx Power Low Alarm(0 dB m) 58 00 For External Cal. 90 00 For External C al. 122 27 10 59 00 For External Cal. 91 00 For External Cal. 123 28 7B Tx Power High Warming(5dBm) 60 00 For External Cal. 92 00 For External Cal. 124 29 87 61 00 For External Cal. 93 00 For Exte rn al Cal. 125 30 31 Tx Power Low Warming (1dBm ) 62 00 For External Cal. 94 00 For External Cal. 126 31 2D 63 00 For External Cal. 95 Check Sum 127

8. All content s are Copyright © 1996 - 2 0 1 9 Wavesplitter Technologies, Inc. All rights reserved . Preliminary and Proprietary www.wavesplitter.com Page 8 of 10 Document Number: 95 - 0189 - V1. 2 1330 nm TX / 1270nm RX, 25GE Di gital Diagnostic 1 - Fiber SM LC SFP28 Transceiver WST - S28 - BX1 - DC EEPROM Series ID Memory Content s (Address A0h) Addr. Hex ASCII Note Addr. Hex ASCII Note Addr. Hex ASCII Note Addr. Hex ASCII Note 0 03 SFP+ 32 20 64 18 Power Level 1, w/ CDR, Uncooled Tx, Txdis, Txfault, LOS 96 00 Vendor specific E EPROM 1 04 33 20 65 1A 97 00 2 07 LC 3 4 20 66 68 25.78Gbps 98 00 3 00 35 20 67 00 99 00 4 00 36 00 NA 68 54 T Serial number: each piece with different serial number 100 00 5 00 37 00 Vendor IEEE OUI 69 4F O 101 00 6 0 0 38 0 F 70 38 8 102 00 7 00 39 0E 71 35 5 103 00 8 00 40 57 W Part Number 72 42 B 104 00 9 00 41 53 S 73 34 4 105 00 10 00 42 54 T 74 30 0 106 00 11 06 64B/66B 43 2D - 75 30 0 107 00 12 FF > 25Gbps 44 53 S 76 3 0 0 108 00 13 00 45 32 2 77 31 1 109 00 14 0A 10km 46 38 8 78 20 110 00 15 64 10km 47 2D - 79 20 111 00 16 00 48 42 B 80 20 112 00 17 00 49 58 X 81 20 113 00 18 00 50 31 1 82 20 114 00 19 00 51 2D - 83 20 115 00 20 57 W Vendor name 52 44 D 84 Y Dat e Code 116 00 21 41 A 53 43 C 85 Y 117 00 22 56 V 54 20 86 M 118 00 23 45 E 55 20 87 M 119 00 24 53 S 56 30 0 Revision, depended on version 88 D 120 00 25 50 P 57 30 0 89 D 121 00 26 4C L 58 30 0 90 20 122 00 2 7 49 I 59 31 1 91 20 123 00 28 54 T 60 05 1330 nm 92 68 Monitoring 124 00 29 54 T 61 32 93 F0 Soft Control and Monitoring 125 00 30 45 E 62 00 Reserved 94 08 SFF - 8472 V12.0 126 00 3 1 52 R 63 Checksum 0 - 62 95 Checksum 64 - 94 12 7 00

Views

  • 529 Total Views
  • 353 Website Views
  • 176 Embedded Views

Actions

  • 0 Social Shares
  • 0 Likes
  • 0 Dislikes
  • 0 Comments

Share count

  • 0 Facebook
  • 0 Twitter
  • 0 LinkedIn
  • 0 Google+

Embeds 5

  • 4 ec2.wavesplitter.com
  • 2 18.220.135.215
  • 9 www.baidu.com
  • 1 www.wavesplitter.com
  • 3 wavesplitter.com